Water Chemistry
Water Analyzer Parameters
Select parameter to see details:
Please click on the product model to see details, literature, and to order parts and reagents.
PARAMETER |
FIXED MODEL |
PORTABLE MODEL |
TECHNOLOGY |
RANGE(S) |
Ammonia |
3046 |
7046 |
Colorimetric |
0-1ppm, 0-10ppm*, 0-50ppm* |
Copper |
3045 |
7045 |
Colorimetric |
0-1000ppb, 0-5ppm, 0-50ppm*, 0-500ppm* |
Dissolved Hydrogen |
9091 |
9091C |
Potentiostatic |
0-1000ppb, 0-20ppm |
Dissolved Oxygen |
9061 9061C 9062 9065 |
9061P 9065C |
Galvanic Luminescent |
0.10ppb-20ppm 0.10ppb-20ppm |
Ethylene Glycol |
9049 |
7049 |
Colorimetric |
0-15ppm, 0-150ppm* |
Hardness |
3051 |
Colorimetric |
0-1000ppb |
|
Hydrazine |
9071 9071C |
Amperometric |
0.10ppb-1ppm |
|
Hydrazine |
3044 |
7044 |
Colorimetric |
0-100ppb, 0-1000ppb* |
Iron |
3048 |
Colorimetric |
0–100ppb, 0–300ppb, 0–3ppm*, 0–30ppm* |
|
Nitrate |
Please contact your local sales support for more information. |
|||
Oil in Water |
2410 |
Nephelometric |
0-99ppm |
|
Phosphate |
3042 |
7042 |
Colorimetric |
0-5ppm, 0-15ppm, 0-150ppm*, 0-750ppm* |
Silica & Phosphate |
9043 |
Colorimetric |
0-500ppb (SiO2), 0-2.4ppm, 0-7ppm (PO4) |
|
Silica |
3041 |
7041 |
Colorimetric |
0-1000ppb, 0-3000ppb, 0-150ppm*, 0-300ppm* |
Sodium |
9033 9031C 9032 |
Ion Selective |
0.01ppb-10ppm
|
Waltron 3040 Series:
Waltron’s 3040 series colorimetric analyzers provide exceptional results for online measuring of silica, phosphate and other parameters. Small size and compact layout make the 3040 series an excellent choice for a variety of applications and environments. Waltron’s 3040 series colorimetric analyzers have been completely redesigned to offer unique and simplified configurations compared to previous models.
Common application points in a boiler system for online silica measurement include: make-up water, condensate, boiler feedwater, saturated steam/main steam and cooling water. Application points for phosphate include: boiler water and cooling water.
REVOLUTIONARY PATENTED TECHNOLOGY Waltron 7040 Series: Our Colorimetric Analyzers (Aqualyzer® Series 7040) are based on the new patented Loop Flow Analysis (LFA) cycle. Common application points in a boiler system for silica measurement include: make-up water, condensate, boiler feedwater, saturated steam/main steam and cooling water. Application points for phosphate include: boiler water and cooling water. LFA technology involves isolating,manipulating and testing a known volume of sample in a closed loop system. A powerful programmable microprocessor allows for customized program cycles,ensuring accuracy and reliability with every application. View wall-mount systems |
|
The Waltron AQUALYZER® 9061 Dissolved Oxygen Analyzer is a state-of-the-art microprocessor-based instrumentation package developed specifically for use in measuring low and high concentrations of dissolved oxygen. It is today’s standard for all low range dissolved oxygen analyzers. True Fully Automatic Calibration Calibration is carried out automatically online and involves no manual operation.An automatic calibration check is performed at a predetermined frequency by the instrument; however, calibration can be initiated at any time manually if needed. Common 9061 Dissolved Oxygen Analyzer application points in a boiler system for online dissolved oxygen measurement include: deaerator, condensate, boiler feed water and economizer inlet. |
|
The WaltronAqualyzer® 9062 Dissolved Oxygen Analyzer is a state-of-the-art microprocessor-based instrumentation package with a compact wet section developed specifically for use in measuring low and high concentrations of dissolved oxygen. It is today’s standard for all low range dissolved oxygen analyzers. True Fully Automatic Calibration Calibration is carried out automatically online and involves no manual operation. An automatic calibration check is performed at a predetermined frequency by the instrument; however, calibration can be initiated at any time manually if needed. Common 9062 Dissolved Oxygen Analyzer application points in a boiler system for online dissolved oxygen measurement include: deaerator, condensate, boilerfeedwater and economizer inlet. |
|
The New Luminescence Oxygen Analyzer 9065 utilizes new luminescent technology for measuring dissolved oxygen in water at ppb levels. Luminescent Dissolved Oxygen Technology Luminescent technology has unique features and benefits compared to traditional dissolved oxygen sensing technologies. The 9065 provides high accuracy with excellent long-term stability. The 9065 Dissolved Oxygen Analyzer can be used in a variety of online analysis applications throughout many different industries. |
|
REVOLUTIONARY PATENTED TECHNOLOGY Our Colorimetric Ethylene Glycol Analyzer (Aqualyzer® Series 9040) is based on the new patented Loop Flow Analysis (LFA) cycle. Waltron Ethylene Glycol analyzers are also capable of measuring Propylene Glycol. LFA technology involves isolating,manipulating and testing a known volume of sample in a closed loop system. A powerful programmable microprocessor allows for customized program cycles,ensuring accuracy and reliability with every application. The Ethylene Glycol Analyzer 9049 is also available in a portable version. |