iso2 HMEI

Water Analyzer Parameters
Select parameter to see details:
Please click on the product model to see details, literature, and to order parts and reagents.

PARAMETER

FIXED

MODEL

PORTABLE

MODEL

TECHNOLOGY

RANGE(S)

Ammonia

3046

7046

Colorimetric

0-1ppm, 0-10ppm*, 0-50ppm*

Copper

3045

7045

Colorimetric

0-1000ppb, 0-5ppm, 0-50ppm*, 0-500ppm*

Dissolved Hydrogen

9091

9091C

Potentiostatic

0-1000ppb, 0-20ppm

Dissolved Oxygen

9061

9061C

9062

9065

9061P

9065C

Galvanic

Luminescent

0.10ppb-20ppm

0.10ppb-20ppm

Ethylene Glycol

9049

7049

Colorimetric

0-15ppm, 0-150ppm*

Hardness

3051

 

Colorimetric

0-1000ppb

Hydrazine

9071

9071C

 

Amperometric

0.10ppb-1ppm

Hydrazine

3044

7044

Colorimetric

0-100ppb, 0-1000ppb*

Iron

3048

 

Colorimetric

0–100ppb, 0–300ppb, 0–3ppm*, 0–30ppm*

Nitrate

Please contact your local sales support for more information.

Oil in Water

2410

 

Nephelometric

0-99ppm

Phosphate

3042

7042

Colorimetric

0-5ppm, 0-15ppm,

0-150ppm*, 0-750ppm*

Silica & Phosphate

9043

 

Colorimetric

0-500ppb (SiO2),

0-2.4ppm, 0-7ppm (PO4)

Silica

3041

7041

Colorimetric

0-1000ppb, 0-3000ppb,

0-150ppm*, 0-300ppm*

Sodium

9033

9031C

9032

 

Ion Selective

0.01ppb-10ppm

 

Waltron 3040 Series:
Waltron’s 3040 series colorimetric analyzers provide exceptional results for online measuring of silica, phosphate and other parameters. Small size and compact layout make the 3040 series an excellent choice for a variety of applications and environments. Waltron’s 3040 series colorimetric analyzers have been completely redesigned to offer unique and simplified configurations compared to previous models.
Common application points in a boiler system for online silica measurement include: make-up water, condensate, boiler feedwater, saturated steam/main steam and cooling water. Application points for phosphate include: boiler water and cooling water.

REVOLUTIONARY PATENTED TECHNOLOGY Waltron 7040 Series:
Our Colorimetric Analyzers (Aqualyzer® Series 7040) are based on the new patented Loop Flow Analysis (LFA) cycle.
Common application points in a boiler system for silica measurement include: make-up water, condensate, boiler feedwater, saturated steam/main steam and cooling water. Application points for phosphate include: boiler water and cooling water.
LFA technology involves isolating,manipulating and testing a known volume of sample in a closed loop system. A powerful programmable microprocessor allows for customized program cycles,ensuring accuracy and reliability with every application.
View wall-mount systems
The Waltron AQUALYZER® 9061 Dissolved Oxygen Analyzer is a state-of-the-art microprocessor-based instrumentation package developed specifically for use in measuring low and high concentrations of dissolved oxygen. It is today’s standard for all low range dissolved oxygen analyzers.
True Fully Automatic Calibration
Calibration is carried out automatically online and involves no manual operation.An automatic calibration check is performed at a predetermined frequency by the instrument; however, calibration can be initiated at any time manually if needed.
Common 9061 Dissolved Oxygen Analyzer application points in a boiler system for online dissolved oxygen measurement include: deaerator, condensate, boiler feed water and economizer inlet.
The WaltronAqualyzer® 9062 Dissolved Oxygen Analyzer is a state-of-the-art microprocessor-based instrumentation package with a compact wet section developed specifically for use in measuring low and high concentrations of dissolved oxygen. It is today’s standard for all low range dissolved oxygen analyzers.
True Fully Automatic Calibration
Calibration is carried out automatically online and involves no manual operation. An automatic calibration check is performed at a predetermined frequency by the instrument; however, calibration can be initiated at any time manually if needed.
Common 9062 Dissolved Oxygen Analyzer application points in a boiler system for online dissolved oxygen measurement include: deaerator, condensate, boilerfeedwater and economizer inlet.
The New Luminescence Oxygen Analyzer 9065 utilizes new luminescent technology for measuring dissolved oxygen in water at ppb levels.
Luminescent Dissolved Oxygen Technology
Luminescent technology has unique features and benefits compared to traditional dissolved oxygen sensing technologies. The 9065 provides high accuracy with excellent long-term stability. The 9065 Dissolved Oxygen Analyzer can be used in a variety of online analysis applications throughout many different industries.
REVOLUTIONARY PATENTED TECHNOLOGY
Our Colorimetric Ethylene Glycol Analyzer (Aqualyzer® Series 9040) is based on the new patented Loop Flow Analysis (LFA) cycle. Waltron Ethylene Glycol analyzers are also capable of measuring Propylene Glycol.
LFA technology involves isolating,manipulating and testing a known volume of sample in a closed loop system. A powerful programmable microprocessor allows for customized program cycles,ensuring accuracy and reliability with every application.
The Ethylene Glycol Analyzer 9049 is also available in a portable version.
آدرس
تلفن
22064015 (9821+)
22148186
22147985 (9821+)
پست الکترونیکی

map

  • نصب ایستگاه سکوی نفتی 4
  • نصب ایستگاه سکوی نفتی 3
  • نصب ایستگاه سکوی نفتی 2
  • نصب ایستگاه سکوی نفتی
  • نصب ایستگاه هواشناسی کشاورزی بنیاد مستضعفان انقلاب اسلامی
  • نصب ایستگاه هواشناسی کشاورزی بنیاد مستضعفان انقلاب اسلامی
  • 1
  • 2
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 12
  • 0

Off Canvas Menu